{{ $t('shop.all.spaetbestellservice.hinweis') }}
Corrosion resistant class KBK | 0 - No corrosion stressing |
Permission |
RCM mark, c UL us - Listed (OL) |
Material information | RoHs compliant |
Nominal operating voltage DC [V] | 24 |
Operating voltage | 19,2 - 30 V DC |
Power input | 100 mA nominal bei 24 V DC |
Max. power supply [A] | 6,0 |
ambient temperature [°C] | 0 to 55 |
Bearing temperature [°C] | -25 to 70 |
Relative humidity |
95 %, Not condensing |
Protection category | IP20 |
Protection class | III |
Product weight [g] | 200 |
Insensitivity test to vibrations | according to EN 61131-2 |
Insensitivity test to shock | according to EN 61131-2 |
Electrical connection technology I/O | Bushing strip, pitch 3.5 mm |
Status displays | LED |
CPU data | Processor 400 MHz |
Digital inputs, quantity | 12 |
Digital inputs, switching logic | Positive logic (PNP) |
Digital inputs, quick number inputs | 2, However max. 180 kHz |
Digital inputs, input signal delay | 3 ms type |
Digital inputs, input voltage / current | 24 V DC |
Digital inputs, nominal value for TRUE | >= 15 VDC |
Digital inputs, nominal value for FALSE | <= 5 VDC |
Digital inputs, potential separation | Yes, opto coupler |
Digital inputs, status display | LED |
Max. line length | 30 m Eingänge |
Digital outputs, quantity | 8 |
Digital outputs, switching logic | Positive logic (PNP) |
Digital outputs, contact | Transistor |
Digital outputs, output voltage | 24 V DC |
Digital outputs, output current | 500 mA |
Digital outputs, potential separation | Yes, opto coupler |
Digital outputs, switching frequency | max. 1 kHz |
Digital outputs, short circuit proof | yes |
Digital outputs, status display | LED |
Report |
CANopen, I-port, IO-Link, Modbus TCP |
Fieldbus interface | CAN bus |
Fieldbus interface, connection technology |
Sub-D, 9 pin, Plug |
Fieldbus interface, transfer rate |
125, 250, 500, 800, 1000kbit/s, can be set via software |
Fieldbus interface, galvanically separated | yes |
USB interface | USB 1.1 |
Ethernet, connection plug | RJ45 |
Ethernet, number | 1 |
Ethernet, data transfer speed | 10/100 Mbit/s |
Ethernet supported protocols | TCP/IP, EasyIP, Modbus TCP |
Programming software | CODESYS provided by Festo V3 |
Programming language |
Instruction list (AWL), Contact diagram (KOP), acc. to IEC 61131-3, Sequence language, Function plan, Structured text |
CE certificate (see declaration of conformity) | to EU EMC directive |
Certified awarding point | UL E239998-D1001 |
IO-Link, report |
Device V 1.0, Master V 1.1 |
IO-Link, communication mode |
configurable using software, Device COM1 (4.8 kBaud), COM2 (38.4 kBaud), COM3 (230.4 kBaud), Master SIO, COM1 (4.8 kBaud), COM2 (38.4 kBaud), COM3 (230.4 kBaud) |
IO-Link, port type |
Device A, Master B |
IO-Link, number of ports |
Device 1, Master 4 |
IO-Link, process data width OUT | Master parameterisable, 2-32 Byte |
IO-Link, process data width IN | Master parameterisable, 2-32 Byte |
IO-Link, minimum cycle time |
Device 3,2 ms, Master 5 ms |
IO link, storage | 2 kByte / port |
IO-Link Master, output current | 3.5 A / port |
IO-Link, connection technology |
Cage Clamp, Plug, Device 3 pin, Master 5-pin |
IO-Link, communication |
C/Q LED green, C/Q LED red |
IO-Link, operation-readiness display |
L+ LED green on, L+ LED green off |
{{ $t('shop.all.gewicht') }} | 200 g / Pièce |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85371091 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}
{{ $t('shop.all.wochenendversand.hinweis') }}